Tube pump extruding provides damaged case case study
In use may encounter the bad news material that tube pump tube regards tube as pump all sorts of attaint, normal circumstance carries normal temperature liquid below next 100 revolution speed that turn, the life that silica gel runs can reach 200-400 hour, the A-60-F pump valve of the entrance can reach 2000-10000 hour. But using a process, because tube pump is soft piping outfitting card is incorrect or the liquid has regular caustic meeting to cause hose pump wears away prematurely and unusual wear away. What is the cause that causes these damage after all? Fix store of oar facility plant today at this point the problem does simple analysis.
A few kinds of circumstances of damaged of tube pump tube are analysed
1, the attaint reason that sees tube pump tube from the crevasse of attaint: If the tube pump tube of attaint looks as if of knife lacerate is a sharp cut euqally, be lacerate of edge of the flange that be mixed by the runner of tube pump head normally so. Because the tube inside pump head is too long,the cause that causes this kind of damaged is normally, when head of tube pump pump runs tube is inside pump head rock bring into contact with by the side of the flange of runner, the ceaseless attrition cut tube side flange. The procedure of this kind of attaint will be exceedingly quick, meet in ten minutes or so normally complete damaged. Accompany the damaged that pump is in charge of, can see a lot of tube broken bits arise inside pump at the same time.
Settle way: 1, when the pump that hold card is in charge of, must make sure the pump valve inside pump head is pulled straight, the hose that won't have had many is by the nest inside pump head. 2, the appropriative on the positional clip that stands by pump head to block a canal in tube pump imports and exports at the same time is plastic card bind round, prevent tube pump tube to become loose in movement run.
2, see attaint reason from the appearance of attaint tube: Tube presents a complete squash, lose spring back ability, tube wall is large attenuate, the surface wears away serious. Because runner gets stuck dead,this kind of phenomenon is normally, tube pump pressure piece there is foreign matter, rotate speed on the face that contacts pump valve and runner exorbitant cause cause. After the runner of tube pump head is died by card, the runner of tube pump has blown tube pump tube directly, the attrition that can raise tube appearance causes tube surface temperature to rise so that mix very high to wear away tube surface, exorbitant temperature also can make tube loses flexibility, the temperature of the generation below extreme circumstance exceeds 140 degrees of above to be able to cause tube to dissolve even be out of shape.
Settle way: Notice whether the movement that examines runner of tube pump head is quick; The attention cleans pump head to press tubal face; Lower the rate that tube pump runs appropriately.
3, see attaint reason from the size of tube pump tube of attaint and appearance: Tube pump tube may carry different liquid, a few liquids can arise to corrode and dissolve to certain tube. If we see tube pump tube becomes fragile, harden, lose flexibility, become angry, dissolve goes up, the phenomenon such as damaged, cause so normally.
Settle way: The tube material that searchs the liquid that won't be carried by oneself to corrode is qualitative, the pump valve that notes store of oar facility plant to a lot of kinds of material pledge can offer an alternative, can provide data of reference of experiment of consistence of most liquid chemistry, provide for future reference of detailed form of chemical photograph deep sex, help your accurate choice tube. The sample that you also can take a few tube goes doing immerse experiment, decide with this tube won't be corroded by the liquid.
The reason that above damages 3 kinds is tube pump compares common problem in use process, if your in use encounters the problem that tube damages also need not anxious, the circumstance that damages according to tube please is done corresponding examination and eliminate.